HomeContact / Information RequestParts & ManualsSupport
test chambers, temperature chambers, humidity chambers, environmental chambers
Temperature OnlyTemperature / HumidityCO2 / LN 2Thermal ShockWalk-In Rooms
Salt Spray / FogLaboratory OvensSpecial ChambersRental / Refurbished

SD Series

Model Working
Volume
Dimensions
H x W x D
Temperature
Range
Temperature
Rise Time
Temperature
Pull-Down
Time
Power
Requirements
Download
Brochure
SD-402 2 Cubic Ft. Internal
15" x 15" x 16"
External
28" x 43" x 28"
-17°C to +200°C
0°F to +392°F
Room ambient to upper limit in approx. 30 minutes Room ambient to lower limit in approx. 25 minutes 1 Phase
120Volt 60 Hz.
1 Phase
100 Volt 50 Hz.
Click to Open
SD-403 3 Cubic Ft. Internal
16" x 20" x 18"
External
28" x 49" x 28"
-17°C to +200°C
0°F to +392°F
Room ambient to upper limit in approx. 30 minutes Room ambient to lower limit in approx. 25 minutes 1 Phase
220Volt 60 Hz.
1 Phase
200 Volt 50 Hz.
Click to Open
SD-405 5 Cubic Ft. Internal
20" x 20" x 22"
External
32" x 49" x 32"
-17°C to +200°C
0°F to +392°F
Room ambient to upper limit in approx. 30 minutes Room ambient to lower limit in approx. 25 minutes 1 Phase
220Volt 60 Hz.
1 Phase
200 Volt 50 Hz.
Click to Open
SD-408 8 Cubic Ft. Internal
24" x 24" x 24"
External
34" x 53" x 34"
-17°C to +200°C
0°F to +392°F
Room ambient to upper limit in approx. 30 minutes Room ambient to lower limit in approx. 25 minutes 1 Phase
220Volt 60 Hz.
1 Phase
200 Volt 50 Hz.
Click to Open
SD-502 2 Cubic Ft. Internal
15" x 15 " x 16"
External
28" x 43" x 28"
-37°C to +200°C
-35°F to +392°F
Room ambient to upper limit in approx. 30 minutes Room ambient to lower limit in approx. 25 minutes 1 Phase
120Volt 60 Hz.
1 Phase
100 Volt 50 Hz.
Click to Open
SD-503 3 Cubic Ft. Internal
16" x 20" x 18"
External
28" x 49" x 28"
-37°C to +200°C
-35°F to +392°F
Room ambient to upper limit in approx. 30 minutes Room ambient to lower limit in approx. 25 minutes 1 Phase
220Volt 60 Hz.
1 Phase
200 Volt 50 Hz.
Click to Open
SD-505 5 Cubic Ft. Internal
20" x 20" x 22"
External
32" x 49" x 32"
-37°C to +200°C
-35°F to +392°F
Room ambient to upper limit in approx. 30 minutes Room ambient to lower limit in approx. 25 minutes 1 Phase
220Volt 60 Hz.
1 Phase
200 Volt 50 Hz.
Click to Open
SD-508 8 Cubic Ft. Internal
24" x 24" x 24"
External
34" x 53" x 34"
-37°C to +200°C
-35°F to +392°F
Room ambient to upper limit in approx. 30 minutes Room ambient to lower limit in approx. 25 minutes 1 Phase
220Volt 60 Hz.
1 Phase
200 Volt 50 Hz.
Click to Open
SD-302 2 Cubic Ft. Internal
15" x 15" x 16"
External
28" x 43" x 28"
-65°C to +200°C
-35°F to +392°F
Room ambient to upper limit in approx. 30 minutes Room ambient to lower limit in approx. 30 minutes.
Room ambient to -40°C in approx. 15 minutes.
1 Phase
120Volt 60 Hz.
1 Phase
100 Volt 50 Hz.
Click to Open
SD-303 3 Cubic Ft. Internal
16" x 20" x 18"
External
28" x 49" x 28"
-65°C to +200°C
-35°F to +392°F
Room ambient to upper limit in approx. 30 minutes Room ambient to lower limit in approx. 30 minutes.
Room ambient to -40°C in approx. 15 minutes.
1 Phase
220Volt 60 Hz.
1 Phase
200 Volt 50 Hz.
Click to Open
SD-305 5 Cubic Ft Internal
20" x 20" x 22"
External
32" x 49" x 32"
-65°C to +200°C
-35°F to +392°F
Room ambient to upper limit in approx. 30 minutes Room ambient to lower limit in approx. 30 minutes 1 Phase
220Volt 60 Hz.
1 Phase
200 Volt 50 Hz.
Click to Open
SD-308 8 Cubic Ft Internal
24" x 24" x 24"
External
34" x 53" x 34"
-65°C to +200°C
-35°F to +392°F
Room ambient to upper limit in approx. 30 minutes Room ambient to lower limit in approx. 40 minutes 1 Phase
220Volt 60 Hz.
1 Phase
200 Volt 50 Hz.
Click to Open

 

Standard Features Optional Extras

   

Home | Contact | Parts | Support | Temperature Only | Temperature/Humidity | CO2/LN2
Thermal Shock | Walk-in Room | Salt Spray | Laboratory Ovens | Special Chambers | Rental
News | Links


 

© 1999-2008  Associated Environmental Systems. Created by Approachnet