| Model |
Working
Volume |
Dimensions
H x W x D |
Temperature
Range |
Rise Time |
Pull-Down
Time |
Power
Requirements |
Download
Brochure |
| SFD-410 |
10 Cubic Ft. |
Internal
40" x 24 " x 21"
External
52" x 60 " x 32" |
-17°C to +200°C
0°F to +392°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 25 minutes |
220 Volt
3 Phase
60 Hz.
|
|
| SFD-416 |
16 Cubic Ft. |
Internal
48" x 24" x 3"
External
58" x 60" x 40" |
-17°C to +200°C
0°F to +392°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 25 minutes |
220 Volt
3 Phase
60 Hz. |
|
| SFD-431 |
31 Cubic Ft. |
Internal
60" x 30" x 30"
External
72" x 74" x 40" |
-17°C to +200°C
0°F to +392°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 25 minutes |
220 Volt
3 Phase
60 Hz. |
|
| SFD-4110 |
110 Cubic Ft. |
Internal
60" x 52" x 60"
External
81" x 122" x 80" |
-17°C to +200°C
0°F to +392°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 25 minutes |
220 Volt
3 Phase
60 Hz. |
 |
| SFD-510 |
10 Cubic Ft. |
Internal
40" x 24" x 21"
External
52" x 60" x 32" |
-37°C to +200°C
-35 °F to +392°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 45 minutes |
220 Volt
3 Phase
60 Hz. |
 |
| SFD-516 |
16 Cubic Ft. |
Internal
48" x 24" x 30"
External
58" x 60" x 40" |
-37°C to +200°C
-35 °F to +392°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 45 minutes |
220 Volt
3 Phase
60 Hz. |
 |
| SFD-531 |
31 Cubic Ft. |
Internal
60" x 30" x 30"
External
72" x 74" x 40" |
-37°C to +200°C
-35 °F to +392°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 45 minutes |
220 Volt
3 Phase
60 Hz. |
 |
| SFD-5110 |
110 Cubic Ft. |
Internal
60" x 52" x 60"
External
81" x 122" x 80" |
-37°C to +200°C
-35 °F to +392°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 45 minutes |
220 Volt
3 Phase
60 Hz. |
 |
| SFD-210 |
10 Cubic Ft. |
Internal
40" x 24" x 21"
External
52" x 60" x 32" |
-65°C to +200°C
-85°F to +392°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 60 minutes |
220 Volt
3 Phase
60 Hz. |
|
| SFD-216 |
16 Cubic Ft. |
Internal
48" x 24" x 30"
External
58" x 60" x 40" |
-65°C to +200°C
-85°F to +392°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 60 minutes |
220 Volt
3 Phase
60 Hz. |
|
| SFD-231 |
31 Cubic Ft. |
Internal
60" x 30" x 30"
External
72" x 74" x 40" |
-65°C to +200°C
-85°F to +392°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 60 minutes |
220 Volt
3 Phase
60 Hz. |
|
| SFD-2110 |
110 Cubic Ft. |
Internal
60" x 52" x 60"
External
81" x 122" x 80" |
-65°C to +200°C
-85°F to +392°F |
Room ambient to upper limit in approx. 20 minutes |
Room ambient to lower limit in approx. 60 minutes |
220 Volt
3 Phase
60 Hz. |
 |