HomeContact / Information RequestParts & ManualsSupport
test chambers, temperature chambers, humidity chambers, environmental chambers
Temperature OnlyTemperature / HumidityCO2 / LN 2Thermal ShockWalk-In Rooms
Salt Spray / FogLaboratory OvensSpecial ChambersRental / Refurbished

SFD Series

Model Working
Volume
Dimensions
H x W x D
Temperature
Range
Rise Time Pull-Down
Time
Power
Requirements
Download
Brochure
SFD-410 10 Cubic Ft. Internal
40" x 24 " x 21"
External
52" x 60 " x 32"
-17°C to +200°C
0°F to +392°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 25 minutes 220 Volt
3 Phase
60 Hz.
 
Click to Open
SFD-416 16 Cubic Ft. Internal
48" x 24" x 3"
External
58" x 60" x 40"
-17°C to +200°C
0°F to +392°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 25 minutes 220 Volt
3 Phase
60 Hz.
 
Click to Open
SFD-431 31 Cubic Ft. Internal
60" x 30" x 30"
External
72" x 74" x 40"
-17°C to +200°C
0°F to +392°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 25 minutes 220 Volt
3 Phase
60 Hz.
 
Click to Open
SFD-4110 110 Cubic Ft. Internal
60" x 52" x 60"
External
81" x 122" x 80"
-17°C to +200°C
0°F to +392°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 25 minutes 220 Volt
3 Phase
60 Hz.
 
Click to Open
SFD-510 10 Cubic Ft. Internal
40" x 24" x 21"
External
52" x 60" x 32"
-37°C to +200°C
-35 °F to +392°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 45 minutes 220 Volt
3 Phase
60 Hz.
 
Click to Open
SFD-516 16 Cubic Ft. Internal
48" x 24" x 30"
External
58" x 60" x 40"
-37°C to +200°C
-35 °F to +392°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 45 minutes 220 Volt
3 Phase
60 Hz.
 
Click to Open
SFD-531 31 Cubic Ft. Internal
60" x 30" x 30"
External
72" x 74" x 40"
-37°C to +200°C
-35 °F to +392°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 45 minutes 220 Volt
3 Phase
60 Hz.
 
Click to Open
SFD-5110 110 Cubic Ft. Internal
60" x 52" x 60"
External
81" x 122" x 80"
-37°C to +200°C
-35 °F to +392°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 45 minutes 220 Volt
3 Phase
60 Hz.
 
Click to Open
SFD-210 10 Cubic Ft. Internal
40" x 24" x 21"
External
52" x 60" x 32"
-65°C to +200°C
-85°F to +392°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 60 minutes 220 Volt
3 Phase
60 Hz.
 
Click to Open
SFD-216 16 Cubic Ft. Internal
48" x 24" x 30"
External
58" x 60" x 40"
-65°C to +200°C
-85°F to +392°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 60 minutes 220 Volt
3 Phase
60 Hz.
 
Click to Open
SFD-231 31 Cubic Ft. Internal
60" x 30" x 30"
External
72" x 74" x 40"
-65°C to +200°C
-85°F to +392°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 60 minutes 220 Volt
3 Phase
60 Hz.
 
Click to Open
SFD-2110 110 Cubic Ft. Internal
60" x 52" x 60"
External
81" x 122" x 80"
-65°C to +200°C
-85°F to +392°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 60 minutes 220 Volt
3 Phase
60 Hz.
 
Click to Open

Note: Humidity available. Specify prefix SHD instead of SFD.
20% to 98% +/-2% RH as limited by a +2°C dew point.
Other voltages available - specify

Standard Features Optional Extras

   

Home | Contact | Parts | Support | Temperature Only | Temperature/Humidity | CO2/LN2
Thermal Shock | Walk-in Room | Salt Spray | Laboratory Ovens | Special Chambers | Rental
News | Links


 

© 1999-2008  Associated Environmental Systems. Created by Approachnet